G 50 and G 60 flowmeters are suitable for measuring small and menium flows of liquids and gases. They can be mounted for horizontal or vertical flow. The PMMA flowmeter is designed with a 1/4 „- 3/8“ threaded connection for the G 50 and 3/8 „- 1/2“ for the G 60.

Principle: From the turbine of the flow meter, the signal is sent to the Hall sensor which is externally mounted on the flow meter without contact with the liquid. Then, the signal is converted to flow by PLC.

Maximal thermal endurance: 70 °C

Maximal working pressure: 10 bar
Accuracy: +/- 2/3

Versions: Pulse output, Display

Type

Version

Water l/min

Threaded
connection G
A (mm)
G 50 Pulse output
0,3 - 3
0,5 - 5
0,8 - 8
1 - 10
1/4”
3/8”
50
G 50-D Display 0,3 - 3
0,5 - 5
0,8 - 8
1 - 10
1/4”
3/8”
138
G 60
Pulse output 2,5 - 25
3,5 - 35
4 - 40
3/8”
1/2”
60
G 60-D
Display 2,5 - 25
3,5 - 35
4 - 40
3/8”
1/2”
148

 

Notice

It is a need to set the flowmeter in the position which is essential for keeping the accuracy of the measurement. The pipe lying in front of and behind of the flowmeter should be flat in the length of 5x of the pipe dimension (5 x DN).

 

 