IN-ECO - Air and Vacuum Components - High pressure side channel blowers/exhausters INW - HPAir and Vacuum Componentswww.in-eco.eu

INW HP high pressure ring blowers / vacuum pumps

Charakteristic:

 

  • wide application
  • oil free operation
  • quiet and low vibration
  • low weight
  • wide range of types and performance
  • easy installation and dismantlement
  • minimum moving parts
  • simple maintenance

 

Applications:

 

  • aeration of waste water systems or pond aeration, aquaculture
  • agitation (aeration) of the solutions by the galvanic technology
  • vacuum cleaning systems – industry cleaners, filters cleaning
  • baths - underwater massage, bubble bath, bubble pilar
  • drying process, air knifes
  • pneumatic conveying system: flour, wheat, powders, synthetic fiber, capsule, etc.
  • handling by the suction curve, leafing and sucking by the vacuum, thermograsp packing
  • textile industry - vacuum cleaning of production waste
  • printing technologies – holding the leaves by sucking   
  • dental technology - suction device

 

 

Principle:

 

Gas is taken into the device via the suction branch with built-in silencer (1). In the side channel (2) the rotor (3) transfers its speed and gas via centrifugal force is pushed toward the compression chamber. This way, along the spiralroute, gas is repeatedly pressed up to the discharge branch (4), from which it is released. With multi-stage blowers, gas flows through multiple compressor chambers placed behind one another, achieving greater pressure differences.

 

 

princip_postranny_kanal

Type  Suction
(m3/h)

Pressure/

vacuum

(mbar)

Motor (IP55), 50Hz, (60Hz)*

Noisi-

ness 

(dB)

Weight

(kg)

 Blower connection

(inner thread)

 Power input

Voltage Current
(kW) (V) (A)
Three phases
INW HP210 H16 47 290/230 0,55 200-240 ∆ / 345-415 Y  2,8 ∆/ 1,6  Y 57 16 G 1¼”
INW HP220 H26 47 490/370 0,81 200-240 ∆ / 345-415 Y   4,0 ∆/ 2,3  Y 58 24 G 1¼”
INW HP220 H56 47 650/370 1,5
200-240 ∆ / 345-415 Y  7,5 ∆/ 4,3  Y 58 28 G 1¼”
INW HP310 H16 66 250/250 0,55 200-240 ∆ / 345-415 Y   2,8 ∆/1,6  Y 57 18 G 1¼”
INW HP310 H26 66 350/280 0,81 200-240 ∆ / 345-415 Y   4,0 ∆/ 2,3  Y 59 18 G 1¼”
INW HP320 H46 65 480/400 1,1 200-240 ∆ / 345-415 Y   5,4 ∆/ 3,1  Y 59 28 G 1¼”
INW HP320 H56 65 540/440 1,5 200-240 ∆ / 345-415 Y    7,5 ∆/ 4,3  Y 59 30 G 1¼”
INW HP410 H16 87 380/300 1,1 200-240 ∆ / 345-415 Y    5,4 ∆/ 3,1 Y 55 22 G 1¼”
INW HP420 H26 87 450/480 1,5 200-240 ∆ / 345--415 Y  7,5 ∆/ 4,3 Y 61 32 G 1¼”
INW HP420 H56 87 750/500 3,3 200-240 ∆ / 345-415 Y 13,0 ∆/ 7,5 Y 61 38 G 1¼”
INW HP510 H16 120 360/310 1,5 200-240 ∆ / 345-415V Y    7,5 ∆/ 4,3 Y 64 28 G 1¼”
INW HP510 H26 120 470/310 2,2 200-240 ∆ / 345-415V Y   11,4 ∆/ 6,6 Y 64 29 G 1¼”
INW HP520 H26 120 460/470 2,2 200-240 ∆ / 345-415V Y   11,4 ∆/ 6,6 Y 64 42 G 1¼”
INW HP520 H77 120 820/500 4 345-415 ∆ 9,0 ∆ 65 52 G 1¼”
INW HP530 H77 120 820/680 4 345-415 ∆ 9,0 ∆ 67 63 G 1¼”
INW HP530 H87 120 1000/680 5,5 345-415 ∆ 11,5 ∆ 67 71
G 1¼”
INW HP610 H16 165 360/340 2,2 200-240 ∆ / 345-415 Y 11,4 ∆/ 6,6 Y 65 33 G 1¼”
INW HP610 H26 165 480/340 3,3 200-240 ∆ / 345-415 Y 13,0 ∆/ 7,5 Y 65 35 G 1¼”
INW HP620 H36 165 500/460 3,3 200-240 ∆ / 345-415 Y 13,0 ∆/ 7,5 Y 67 51
G 1¼”
INW HP620 H57 165 740/460 5,7 345-415 ∆
12,5  ∆ 68 67
G 1¼”
INW HP630 H67 170 1040/730 7,5 345-415 ∆ 16,0  ∆ 72 86 G 1¼”
INW HP351 H26 315 270/290
3
200-260 ∆ / 350-450 Y
11,4 ∆/ 6,5 Y
65
50
G 2 ½”
INW HP351 H37
315 390/350 4 350-450 ∆ / 610-725 Y
 8,4 ∆/ 4,8 Y 65 85
G 2 ½”
INW HP351 H47 315 500/350  5,5 350-450 ∆ / 610-725 Y
11,1 ∆/ 6,4 Y
65 90
G 2 ½”
INW HP352 H26
320 190/230  3 200-260 ∆ / 350-450 Y 11,4 ∆/ 6,5 Y  68  68 G 2 ½”
INW HP352 H37
320
310/350
 4 350-450 ∆ / 610-725 Y
8,4 ∆/ 4,8 Y
 69  79 G 2 ½”
INW HP352 H47 320 480/530
 5,5 350-450 ∆ / 610-725 Y 11,1 ∆/ 6,4 Y
 71  90 G 2 ½”
INW HP352 H57 320 700/530
 7,5 350-450 ∆ / 610-725 Y  15,0 ∆/ 8,7 Y  71  127 G 2 ½”
INW HP352 H67
320
870/530  11 350-450 ∆ / 610-725 Y 22,0 ∆/ 12,7 Y
 72  130 G 2 ½”
INW HP353 H37
320 250/300
4
350-450 ∆ / 610-725 Y 8,4 ∆/ 4,8 Y  69 82 G 2 ½”
INW HP353 H47 320
410/490  5,5 350-450 ∆ / 610-725 Y 11,1 ∆/ 6,4 Y
 71 93 G 2 ½”
INW HP353 H57
320 620/680
 7,5 350-450 ∆ / 610-725 Y 15,0 ∆/ 8,7 Y  71 153 G 2 ½”
INW HP353 H67 320 1020/680
 11 350-450 ∆ / 610-725 Y 22,0 ∆/ 12,7 Y
 72 170 G 2 ½”
INW HP551 H26 480 120/130 3,0 200-260 ∆ / 350-450 Y 11,4 ∆/ 6,5 Y 69 66 G 3”
INW HP551 H37 480 200/230 4,0 350-450 ∆ / 610-725 Y 8,4 ∆/ 4,8 Y 69 78 G 3”
INW HP551 H47 480 330/380 5,5 350-450 ∆ / 610-725 Y 11,1 ∆/ 6,4 Y 69 88 G 3”
INW HP551 H57 480 500/380 7,5 350-450 ∆ / 610-725 Y 15,0 ∆/ 8,7 Y 69 96 G 3”
INW HP552 H47 480 220/270 5,5 350-450 ∆ / 610-725 Y 11,1 ∆/ 6,4 Y 70 118 G 3”
INW HP552 H57 480 370/450 7,5 350-450 ∆ / 610-725 Y 15,0 ∆/ 8,7 Y 70 126 G 3”
INW HP552 H67 480 630/530 11,0 350-450 ∆ / 610-725 Y 22,0 ∆/ 12,7 Y 70 145 G 3”
INW HP552 H77 480 890/530 15,0 350-450 ∆ / 610-725 Y 30,5 ∆/ 17,3 Y 70 156 G 3”
INW HP553 H57 480 280/380 7,5 350-450 ∆ / 610-725 Y 15,0 ∆/ 8,7 Y 71 142 G 3”
INW HP553 H67 480 540/610 11,0 350-450 ∆ / 610-725 Y 22,0 ∆/ 12,7 Y 71 167 G 3”
INW HP553 H77 480 830/610 15,0 350-450 ∆ / 610-725 Y 30,5 ∆/ 17,3 Y 71 180 G 3”
INW HP553 H87 480 1020/610 18,5 350-450 ∆ / 610-725 Y 37,0 ∆/ 21,0 Y 71 195 G 3”
Single phase
 INW HP210 A75 47 290/230 0,55 220-240 6,5 57 17 G 1¼”
INW HP220 A75 47 600/370 1,5 220-240 9,7 58 32 G 1¼”
INW HP310 A71 66 350/250 0,94 220-240 9,0 57 21
G 1¼”
INW HP320 A75 65 550/400 1,5 220-240 9,7 59 33 G 1¼”
INW HP410 A41 87 380/300 1,1 220-240 10,1 55 23 G 1¼”

 

* 60 Hz please request this information.

 

INW ring blowersDatasheets (pdf/2MB)

 

INW HP_high pressure blowers / exhausters can be applied as vacuum pump and compressor in continuous operation over the total stated performance curve range. The motors are available as standard for the input voltage range of 50 and 60 Hz and for protection category IP 54 (protection against dust and splashing water).

Motors are designed according to the DIN EN 60 034/ IEC 34-1 and temperature class F. For the three phase machines the tolerance +/- 10% for fixed voltage and for +/- 5% voltage range. The single phase machines are designed with a +/- 5% tolerance. If only 90% of the maximum allowed pressure will be used for continuous operating then the allowed voltage range add to +/- 10%. The frequency tolerance is maximum +/- 2%.

 

Performance curves

Side channel high pressure blowers/pumps INW


Performance curves Side channel high pressure blowers/pumps INW

Heat curves

Side channel high pressure blowers/pumps INW

 


Heat curves Side channel high pressure blowers/pumps INW

Dimensions

Side channel high pressure blowers/pumps INW

Dimensions Side channel high pressure blowers/pumps INW

If you are interested in price offer, please, fill in our inquiry form.

logo_rohs_55

INW blowers/exhausters meet Directive 2002/95/EC of European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

logo-ce_46

INW blowers/exhausters conform to the European Community’s Machinery Directive (CE).

© 1996 - 2024 IN-ECO. All rights reserved. | E-mail: info@in-eco.eu